Auto Ranging Conductivity/TDS/Resistivity/Salinity/°C Analyzer

Model : µConCal50 | Make : ANALAB | HSN Code : 90278990

Supplied with Conductivity Cell K = 1.0, Temperature Probe, Electrode Stand consists of Clamp, Base Plate & Rod, Dust Cover, DC Adaptor, Operational & Instruction Manual with SOP, Calibration Test Certificate (Without Traceability Document) and Warranty Card.

Technical Specification

  • Conductivity Range :
    ● 0-20.00, 20-200.0, 200-2000 µS/cm, 2-20.000, 20-200, 200-2000 mS/cm for K=1.0
    ● 0-10.00, 10-100.0, 100-1000 µS/cm, 1-10.000, 10-100, 100-1000 mS/cm for K=0.5
    ● 0-2.00, 2-20.0, 20-200, 200-2000 µS/cm, 2-20, 20-200 mS/cm for K=0.1
    (Range value change depending upon cell selection)
  • Conductivity Resolution : 00.001, 0.01, 0.1 µS/cm & 0.001, 0.01, 0.1, 1 mS/cm
  • TDS Range : 0 to 10, 100, 1000, 10000 ppm, 100ppt, 1000ppt
    (Depending on TDS Factor)
  • TDS Resolution : 0.001, 0.01, 0.1 ppm & 0.001, 0.01, 0.1 ppt (1ppt=1000ppm)
  • Resistivity Range : 20.00 MΩ to 50.00 KΩ, 5.00 KΩ, 500.00 Ω, 50.00 Ω, 0.50 Ω
  • Resistivity Resolution : 0.001
  • Salinity : 0.01 to 80000.0 ppm NaCl
  • Temperature Range : -5.0 to 130.0°C
  • Temperature Resolution : 0.1°C
  • Temperature Compensation : Auto / Manual
  • Temperature Coefficient : Six - 0-10.000 % per °C (Adjustable) - One Per Range
  • Temperature Calibration : In-built software and can be calibrated by users
  • Number of Range : Six
  • Calibration Standard : Six Conductivity & TDS Standard - One Per Range
  • Calibration Factor : Six – One Per Range
  • Range Selection : Auto / Manual
  • Suitable Cell Constant : 0.1, 0.5 & 1.0 K
  • Adjustable Cell Constant : 0.09 to 0.11 K, 0.45 to 0.55 K & 0.90 to 1.1 K
  • Conductivity to TDS Conversion : 0.40000 to 1.00000 (Adjustable Factor)
  • Reading : Conductivity at actual temperature and at 25°C, TDS, Resistivity & Salinity with scrolling display.
  • TDS Calibration & Analysis : In Separate Mode
  • Error Messages : “Wrong Standard / Cell”, “Cell Short”, “Cell Open”, “Try Upper Range”, “Try Lower Range”, “Temperature Probe Error” & “Low Memory”
  • Display : 20 x 4 Line Alphanumeric Backlit LCD.
  • Keypad : Membrane waterproof polycarbonate soft touch keypad compliance to UL/ROHS.
  • Calibration Data Storage : Non-Volatile Memory which can store, print & view with calibration date & time, cell constant, calibration range, standard conductivity solution, measured conductivity at 25°C, actual temperature, calibration factor, instrument serial number, instrument ID, model number etc.
  • Analysis Data Storage : More than 750 analysis data can be stored with corresponding calibration data with company name, analysis date & time, record number, batch number / ID, sample name, username, conductivity at 25°C and conductivity at actual temperature, % Tempco, conductivity to TDS conversion factor, TDS, resistivity, salinity, instrument serial number, instrument ID, model number etc. Secondly, analysis data can be print online without saving analysis.
  • Searching of data : With record number, batch number, Date and by scrolling
  • Report Formation : As per GLP Compliance
  • Password Protection : Date & Time, Calibration Mode, Analysis Mode & Delete Stored Analysis Data.
  • Printer Interface : Centronics Parallel Port / Serial (RS-232 C) Port
  • Printer : 40 / 80 Column Dot Matrix Printer (Printer to be procure optionally)
  • Power Supply : DC Adaptor