Model : µFlameCal100 | Make : ANALAB | HSN Code : 90275010
Supplied with Two Filters (Na and K), Inbuilt Air Supply Unit, Atomizer Tube, Sample Beaker (06 Nos.), Gas Lighter, LPG
Tube, Power Cord, ANALABsafe software, USB Interface Cable, Operational & Instruction Manual with SOP, Calibration Test
Certificate (Without Traceability Document) and Warranty Card.
Technical Specification
Element Range : Na, K, & Li : 1-200 ppm, Ca : 15-300 ppm, Ba : 50-3000 ppm
Sensitivity : Na : 0.5 ppm, K : 0.5 ppm, Li : 0.5 ppm, Ca : 15 ppm, Ba : 50 ppm
Filter Selection : Automatic by soft touch key
Resolution : 0.1 ppm
Detector : Silicon Photodiode
Linearity : Better than 2%
Unit of Measurement : ppm, mg/L, meq/L and mmol/L
Calculation of Concentration : In built with system & can be measure by Sample Weight & Dilution Factor.
Reproducibility : <1% Coefficient of Variation (CV) for 20 consecutive samples using 10 ppm Na set as maximum standard & Barium 3% Coefficient of Variation (CV) for 20 consecutive samples of Concentrations between 50 to 199 ppm.
Stability : <2% drift over 5min when continuously aspirating 10 ppm sample Specificity Interference from Na/K and Li.
Curve Fitting Accuracy : <1% error when 3 ppm Na/K and 5 ppm Li are set as maximum standards and can measure calculation of curve coefficient automatically.
Correlation Factor : Possible with System
Quick Calibration Facility : With Highest standard
Calibration : Up to 05 standards per Element with Curve Fitting Software in built with Instrument. (Automatic calculation of curve coefficient)
Measurement of Sample : Multi elements in single aspiration OR one by one.
Calibration of Sample : Multi elements in single aspiration OR one by one.
Ignition System : Auto Igniter
Auto LPG Shut-off at Power Off : Safety feature in case of sudden power failure
Flame Type : LPG & Dry Oil Free Air
Auto Flame ON / OFF Detection : Audio and Visual Alarm
Gas Control : Adjustable with Regulator
Atomizer : Axial Flow Type
Air Flow Monitoring Facility : 4 – 6 ml/min., In-built with Instrument
Error Messages : “LPG is Off”, “Home Detection”, “Memory Full”, “Flame is Off”, “Do Warm-up”, “In Correct Standard” & “Enter in Range”.
Air Supply Unit (In-built) : Consist of Air Compressor, Pressure Gauge, Pressure Regulator, Moisture Filter, PU Tube (2 Meters) and Air filter with moisture absorbent catalyst.
Calibration Data Storage : Non-Volatile Memory which can store, print & view last calibration data, calibration date & time, company name, calibration done by, calibration standard etc.
Analysis Data Storage : More than 1500 analysis data can be stored with corresponding calibration data, analysis date & time, record number, Batch number / ID, sample name, username, assigned method number, Corresponding Calibration data of lower & higher standard, Sample Result, Dilution factor, Sample Weight, Calculation of Concentration, instrument ID, serial number, model number, make, etc. Secondly, analysis data can be print online without saving in Instrument.
Searching of data : With record number, batch number, date, date range and by scrolling.
Report Formation : As per GLP Compliance
21 CFR Part-11 Compliance : ● In-built with system for ease of operation without PC.
● 2 Admin, 10 Reviewers, 40 Users & 1 Manufacturer with individual Login ID & Passcode.
● Audit trail can store more than 5000 lines in instrument.
● Audit trail includes action taken, date & time, action taken by whom.
● Audit trail can be transfer to PC through ANALABsafe software and can print on 40 / 80 column dot matrix printer for record.
● Admins can set up operation permission of each Users & Reviewers.
● Strict Admins control to audit and monitor usage and access.
● Audit trail record can be printed with Date, Date Range and by individual User’s ID.
● Once Audit trail transfer to the PC or Printer, system will delete Audit trail records and before final deletion, the system will give warning twice.
● Data integrity with database capability to store Analysis Data, Calibration Data, Calibration and Analysis Method, Audit trail and Passcode in instrument.
● No direct access to data from outside the instrument, thereby creating a closed system.
● Audit traceability to ensure that the device and results are appropriately handled.
● Auto User’s logout after defined Logout time.
● Auto Users & Reviewers block when password is entered incorrectly 3 consecutive times
Printer Interface : Centronics Parallel Port / Serial (RS-232 C) Port
Printer : 40 / 80 Column Dot Matrix Printer (Printer to be procure optionally)
PC Interface : USB Type - B
PC Connectivity : By USB Interface Cable with Driver, ANALABsafe software to transfer Analysis data in GLP format, Calibration data and Audit trail from Instrument to PC in non-editable format (Cannot Delete)