Microcontroller Based Flame Photometer

Model : µFlameCal10 | Make : ANALAB | HSN Code : 90275010

Supplied with Two Filters (Na and K), Air Supply Unit, Atomizer Tube, Sample Beaker (06 Nos.), Gas Lighter, LPG Tube, Power Cord, Operational & Instruction Manual with SOP, Calibration Test Certificate (Without Traceability Document) and Warranty Card.

Technical Specification

  • Element Range : Na, K, & Li : 1-100 ppm, Ca : 15-100, Ba : 50-1000 ppm ppm
  • Sensitivity : Na : 0.5 ppm, K : 0.5 ppm, Li : 0.5ppm, Ca : 15 ppm, Ba : 50 ppm
  • Filter Selection : Automatic by soft touch key
  • Resolution : 0.1 ppm
  • Detector : Silicon Photodiode
  • Linearity : Better than 2%
  • Unit of Measurement : ppm
  • Reproducibility : <1% Coefficient of Variation (CV) for 20 consecutive samples using 10 ppm Na set as maximum standard & Barium 3% CV for 20 consecutives samples of Concentrations between 50 to 199 ppm.
  • Curve Fitting Accuracy : <1% error when 3 ppm Na/K and 5 ppm Li are set as maximum standards.
  • Quick Calibration Facility : With highest standard
  • Dilution Factor : Yes, by soft touch keypad
  • Calibration : Upto 03 standards per Elements with Curve Fitting Software in-built with Instrument. (Automatic calculation of curve coefficient)
  • Ignition System : Automatic
  • Flame Type : LPG & Dry Oil Free Air
  • Auto Flame ON / OFF Detection : Audio and Visual Alarm
  • Gas Control : Adjustable with regulator
  • Atomizer : Axial Flow Type
  • Air Flow Monitoring Facility : 4 – 6 ml/min., In-built with Instrument
  • Error Messages : “Home Detection”, “Memory Full”, “Flame is Off”, “Value Out of Limit”, “Do Warm-up”, “In Correct Standard” & “Enter in Range”.
  • Display : 16 x 2 Line Alphanumeric LCD with Backlit
  • Keypad : Membrane waterproof polycarbonate soft touch keypad compliance to UL/ROHS
  • Air Supply Unit (Separate Unit) : Consist of Air Compressor, Pressure Gauge, Pressure Regulator, Moisture Filter, PU Tube (2 Meters) and Air filter with moisture absorbent catalyst.
  • Calibration Data Storage : Non-Volatile Memory which can store, last calibration data for all elements.
  • Analysis Data Storage : More than 500 analysis data which can be viewed & Print, company name, analysis date & time, record number, *Username, *Sample Name, *Bath Number/ID, Calibration data of lower & higher standard, result, Dilution factor, instrument serial number, Instrument Make & Model & *Signature etc. Secondly, analysis data can be print online without saving analysis data in Instrument.
    (*: Not possible to enter data by instrument keypad but it will be handwritten)
  • Searching of data : With record number by scrolling.
  • Report Formation : As per Non-GLP Compliance
  • Printer Interface : Centronics Parallel Port / Serial (RS-232 C) Port
  • Printer : 40 / 80 Column Dot Matrix Printer (Printer must procure optionally)
  • Power Supply : 230VAC ± 10%, 50 Hz