Multiparameter Analyzer
(pH/ORP/mV/Conductivity/TDS/°C Analyzer)

Model : µMultiCal10 | Make : ANALAB | HSN Code : 90278990

Supplied with Combination Glass pH Electrode (0-70ºC), Conductivity Cell K=1.0, Standard Buffer Tablets, Temperature Probe, Electrode Stand consists of Clamp, Dust Cover, DC Adaptor, Operational & Instruction Manual with SOP, Calibration Test Certificate (Without Traceability Document) and Warranty Card.

Technical Specification

  • pH Range : -2.000 to 20.000 pH
  • Selectable Resolution : 0.1 / 0.01 / 0.001 pH
  • Relative Accuracy : ±0.02 / 0.002 pH
  • mV/ORP Range – mV/RmV : ±2000.0
  • ORP : EH auto calibration to standard hydrogen electrode
  • Resolution : 0.1
  • Relative Accuracy : ±0.2 mV or 0.05%, whichever is greater.
  • Slope : 80 - 120 %
  • Auto Buffer Recognition :
    1) 6.86 / 7.00 & 4.01 / 9.18 / 10.01 pH @ 25ºC for two points
    2) 4.01, 6.86 / 7.00 & 9.18 / 10.01 pH @ 25ºC for three points
  • Calibration Reminder Alarm : 0-99 hours
  • Result : Auto / Manual
  • pH Buffer Standard : US / NIST / EURO / DIN
  • Short Link : Provided to diagnose the problem either with Instrument OR Electrode.
  • Conductivity Range :
    ● 0-20.00, 20-200.0, 200-2000 µS/cm, 2-20.000, 20-200, 200-2000 mS/cm for K=1.0
    ● 0-10.00, 10-100.0, 100-1000 µS/cm, 1-10.000, 10-100, 100-1000 mS/cm for K=0.5
    ● 0-2.00, 2-20.0, 20-200, 200-2000 µS/cm, 2-20, 20-200 mS/cm for K=0.1
    (Range value change depending upon cell selection)
  • Conductivity Resolution : 0.001, 0.01, 0.1 µS/cm & 0.001, 0.01, 0.1, 1 mS/cm
  • TDS Range : 0 to 10, 100, 1000, 10000 ppm, 100ppt, 1000ppt
    (Depending on TDS Factor)
  • TDS Resolution : 0.001, 0.01, 0.1 ppm & 0.001, 0.01, 0.1 ppt (1ppt=1000ppm)
  • Number of Range : Six
  • Calibration Standard : Six Conductivity & TDS Standard - One Per Range
  • Calibration Factor : Six – One Per Range
  • Range Selection : Auto / Manual
  • Suitable Cell Constant : 0.1, 0.5 & 1.0 K
  • Adjustable Cell Constant : 0.09 to 0.11 K, 0.45 to 0.55 K & 0.90 to 1.1 K
  • Conductivity to TDS Conversion : 0.40000 to 1.00000 (Adjustable Factor)
  • Temperature Coefficient : Six - 0-10.000 % per °C (Adjustable) – One Per Range
  • Reading : Conductivity at actual temperature and at 25°C & TDS with scrolling display.
  • Temperature Range : -5.0 to 130.0°C
  • Temperature Resolution : 0.1°C
  • Temperature Compensation : Auto / Manual
  • Temperature Calibration : In-built software and can be calibrated by users
  • Calibration & Analysis : pH Mode, ORP Mode, Conductivity Mode and TDS Mode.
  • Error Message : “Wrong standard / Cell”, “Cell Short”, “Cell Open”, “Try Upper Range”, “Try Lower Range”, “Bad Buffer / Electrode”, “pH Over Range”, “Temperature Probe Error”, “In-complete Calibration”, “Calibration Due”, & “Low Memory”.
  • Display : 16 x 2 Line Alphanumeric Backlit LCD.
  • Keypad : Membrane waterproof polyester soft keypad compliance to UL/ROHS.
  • Calibration Data Storage : Non-Volatile Memory can store, print & view calibration details.
  • Analysis Data Storage : More than 500 analysis data which can be viewed & Print, company name, analysis date & time, record number, *Username, *Sample Name, *Bath Number/ID, pH, mV, temperature reading, calibration data with date & time, conductivity at 25°C and conductivity at actual temperature, % Tempco, conductivity to TDS conversion factor, TDS, instrument serial number, Instrument Make & Model & *Signature etc. Secondly, analysis data can be print online without saving analysis data in Instrument.
    (*: Not possible to enter data by instrument keypad but it will be handwritten)
  • Searching of data : With record number, batch number, date, date range and by scrolling.
  • Report Formation : As per Non-GLP Compliance
  • Printer Interface : Centronics Parallel Port / Serial (RS-232 C) Port
  • Printer : 40 / 80 Column Dot Matrix Printer (Printer to be procure optionally)
  • Power Supply : DC Adaptor