Tablet Dis-integration Test Apparatus
(Independent Motor & Timer for Two Basket)

Model : µTDTCal50 | Make : ANALAB | HSN Code : 90318000 Supplied with 1000 ml Glass Beaker – 02 Nos., 6 tube basket assembly – 02 Nos., Guided Discs – 12 Nos., Temperature Probe – 02 Nos., Power Cord, Operational & Instruction Manual with SOP, Calibration Test Certificate (Without Traceability Document) and Warranty Card.

Technical Specification

  • Stroke Length : 55mm ±2mm
  • Number of Stroke Frequency Rate : 29–32 Cycles Per Min.
  • Readable Temperature Range : 10.0°C to 50.0°C
  • Temperature Control Range : 30.0°C to 40.0°C
  • Temperature Accuracy : ±0.2°C
  • Temperature Resolution : 0.1°C
  • Programmable Timer : 1 sec. to 9 hrs.: 59 min.: 59 sec.
  • Heating time to 37°C : Less than 20 min.
  • Heating Technology : Bathless
  • Heater Capacity : DC Heater-150 Watt
  • Heating : Bathless heating results into fast heating and save water
  • Temperature Sensor : PT-100
  • Number of Beaker : Two – Capacity 1000 ml
  • Number of Motor : Two
  • Number of Timer : Two
  • Number of Basket : Two (Six Test Tube Per Basket)
  • Control of Basket : Independent Motor & Timer for Two Basket
  • Display : 40 x 4 Line Alphanumeric Backlit LCD
  • Loading of Basket : Magnetised for ease of cleaning
  • Illumination : White Light for better visibility of dis-integration process
  • Parking of Basket : Automatic after completion of test
  • Keypad : Membrane waterproof polycarbonate soft touch keypad compliance to UL/ROHS
  • Pharmacopeia Complies : As per USP, IP, Ph. Eur.
  • Method : 40 analysis method with View, Print & Delete facility
  • Password Protection : Delete Stored Protocol, Delete Stored Data, Date & Time
  • Date : 12/24 Hours Format
  • Time : Real time clock
  • Searching of data : With record number, batch number, Date and by scrolling
  • Report Formation : As per GLP Compliance
  • Analysis Data Storage : More than 750 data can be store in non-Volatile Memory which can print & view company name, print date and time, analysis date & time, record number, batch number / ID, sample name, username, pharmacopeia, assigned method number, analysis done on, model number, serial number, instrument ID, individual dis-integration time of each sample when you did visually detect the dis-integration of the tested sample by simply pushing the relevant character key (1-6), Basket Set & Actual Temperature, Media Used, etc. Secondly, data can print online without saving analysis data in the instrument.
  • Printer Interface : Serial (RS-232 C) Port
  • Printer : 40 / 80 Column Dot Matrix Printer (Printer must procure optionally)
  • Power Supply : 230VAC ± 10%, 50 Hz
  • Dimensions : 460 x 450 x 710 mm (L x W x H)
  • Weight : 24.5 Kgs (Net) & 29.0 Kgs (Gross)