pH/mV/°C/ORP Analyzer
(Three/Five Point Calibration)

Model : µpHCal10+ | Make : ANALAB | HSN Code : 90278990

Supplied with Combination Glass pH Electrode (0-70ºC), Standard Buffer Tablets (7.00 pH, 4.01 pH & 9.18 pH), Temperature Probe, Electrode Stand consists of Clamp, Base Plate & Rod, Dust Cover, DC Adaptor, Operational & Instruction Manual with SOP, Calibration Test Certificate (Without Traceability Document) and Warranty Card.

Technical Specification

  • pH Range : -2.000 to 20.000 pH
  • Selectable Resolution : 0.1 / 0.01 / 0.001 pH
  • Relative Accuracy : ±0.02 / 0.002 pH
  • mV / ORP Range – mV / RmV : ±2000.0
  • ORP : EH auto calibration to standard hydrogen electrode
  • Resolution : 0.1
  • Relative Accuracy : ±0.2 mV OR 0.05%, whichever is greater
  • Temperature Range : -5.0 to 130.0ºC
  • Resolution : 0.1°C
  • Relative Accuracy : ±0.1ºC
  • Temperature Compensation : Auto / Manual
  • Temperature Calibration : In-built software and can be calibrated by users
  • Slope : 80-120 %
  • Total Numbers of Slope : 4 slopes for Five-point calibration & 2 slopes for Three-point calibration.
  • Auto Buffer Recognition :
    1) 4.01, 6.86 / 7.00, 9.18 / 10.01 pH @25ºC for Three points.
    2) 1.68, 4.01, 6.86 / 7.00, 9.18 / 10.01 & 12.45 pH @25ºC for Five points.
  • Calibration Reminder Alarm : 0-99 hours
  • Display Reading : Simultaneous - pH, mV & Temperature.
  • Buffer Standard : US / NIST & EURO
  • Error Messages : “Bad Buffer / Electrode”, “Temperature Probe Error”, “In-complete Calibration”, “Calibration Due”, “Low Memory” & “pH Over Range”.
  • Short Link : Provided to diagnose the problem either with Instrument OR Electrode.
  • Display : 16 x 2 Line Alphanumeric Backlit LCD
  • Keypad : Membrane waterproof polycarbonate soft touch keypad compliance to UL/ROHS
  • Calibration Data Storage : Non Volatile Memory which can store, print & view calibration date & time, calibration point, pH, mV, temperature, % slope, instrument ID, model name etc.
  • Analysis Data Storage : More than 500 analysis data which can be viewed & Print, company name, analysis date & time, record number, *Username, *Sample Name, *Bath Number/ID, pH, mV, temperature reading, Corresponding Calibration Data, instrument serial number, Instrument Make & Model & *Signature etc. Secondly, analysis data can be print online without saving analysis data in Instrument.
    (*: Not possible to enter data by instrument keypad but it will be handwritten)
  • Searching of data : With record number by scrolling.
  • Report Formation : As per Non-GLP Compliance
  • Printer Interface : Centronics Parallel Port / Serial (RS-232 C) Port
  • Printer : 40 / 80 Column Dot Matrix Printer (Printer to be procure optionally)
  • Power Supply : DC Adaptor